Skip to main content
Version: edge

metrics

The metrics connector collects and forwards system metrics and can be used by user defined logic to expand on the set of metrics collected.

Configuration

We use the standard definition of the metrics connector from the standard library

use tremor::connectors;

create connector metrics from connectors::metrics;

...

connect /connector/metrics to /pipeline/my_metrics

...

Format

The general form of metrics events is as follows:

{"measurement":"connector_events","tags":{"connector":"in","port":"err"},"fields":{"count":0},"timestamp":1650402845610254000}
{"measurement":"events","tags":{"pipeline":"main","node":"out","direction":"input","port":"in"},"fields":{"count":7},"timestamp":1650402845610254000}
{"measurement":"events","tags":{"pipeline":"main","node":"process","direction":"output","port":"out"},"fields":{"count":7},"timestamp":1650402845610254000}
{"measurement":"connector_events","tags":{"connector":"out","port":"in"},"fields":{"count":8},"timestamp":1650402845610254000}

Where:

{
"measurement":"connector_events", # The name of the measure
"tags":{"connector":"out","port":"in"}, # Measure specific tags or labels
"fields":{"count":20}, # Measure specific fields
"timestamp":1650402945610254000} # Optional Timestamp
}

How do i capture system metrics to standard output?

Capture and redirect system metrics and redirect to standard output

capture.troy
define flow main
flow
use integration;
use std::time::nanos;
use tremor::connectors;

# connector definitions
define connector in from metronome
with
metrics_interval_s = 3,
config = { "interval": nanos::from_seconds(1) }
end;

define connector out from file
with
metrics_interval_s = 3,
codec = "json-sorted",
postprocessors = ["separate"],
config = {
"path": "events.log",
"mode": "write"
}
end;

# pipeline definitions
define pipeline main
args
metrics_interval_s = 3
pipeline
#!config metrics_interval_s = 3

select event from in into out;
end;

define pipeline metrics
into
out, err, exit
pipeline
define script process
script
# exit if we have at least 10 events
match state of
case %{ measurement == "exit" } => # exit hook via a poisoned measurement name
# Won't fire via the `metronome`
emit {"EXIT": "NOW"} => "exit"
default =>
event # emit state => "out"
end
end;

create script process;

select event from in into process;
select event from process/out into out;
select event from process/exit into exit;
select event from process/err into err;

end;

# creating connectors
create connector in;
create connector out;

create connector exit from connectors::exit;
create connector metrics from connectors::metrics;
create connector stdio from connectors::console;

# creating pipelines
create pipeline main;
create pipeline metrics;

# connects
connect /connector/in to /pipeline/main;
connect /pipeline/main/out to /connector/out;

connect /connector/metrics to /pipeline/metrics;
# catching other outputs, just in case
connect /pipeline/metrics/out to /connector/stdio/stdout;
connect /pipeline/metrics/err to /connector/stdio/stderr;

# exit when we have all events
connect /pipeline/metrics/exit to /connector/exit;
connect /pipeline/metrics/exit to /connector/stdio/stdout;

end;

deploy flow main;